You're $50 Away from Free Shipping!
Menu
Tjernlund AS1 AireShare Room-to-Room Fan Ventilator - 70 CFM Hardwired Ventilation System for Home, Office & Basement Air Circulation
Tjernlund AS1 AireShare Room-to-Room Fan Ventilator - 70 CFM Hardwired Ventilation System for Home, Office & Basement Air CirculationTjernlund AS1 AireShare Room-to-Room Fan Ventilator - 70 CFM Hardwired Ventilation System for Home, Office & Basement Air CirculationTjernlund AS1 AireShare Room-to-Room Fan Ventilator - 70 CFM Hardwired Ventilation System for Home, Office & Basement Air CirculationTjernlund AS1 AireShare Room-to-Room Fan Ventilator - 70 CFM Hardwired Ventilation System for Home, Office & Basement Air Circulation

Tjernlund AS1 AireShare Room-to-Room Fan Ventilator - 70 CFM Hardwired Ventilation System for Home, Office & Basement Air Circulation

$96.77 $175.96 -45%

Delivery & Return:Free shipping on all orders over $50

Estimated Delivery:7-15 days international

People:14 people viewing this product right now!

Easy Returns:Enjoy hassle-free returns within 30 days!

Payment:Secure checkout

SKU:71947809

Guranteed safe checkout
amex
paypal
discover
mastercard
visa

Product Description

Transfer air to rooms that are too hot or cold. Extend comfort from ductless split systems and PTAC’s to rooms without air handlers. Also enhance the distribution of heat from fireplaces and stoves. Quiet tangential blower fits into walls as little as 3” deep. 60 CFM.

Product Features

Transfer air through interior walls from room to room

Use with ductless cooling and heating to transfer comfort to adjacent rooms

Quiet, low watt blower. Dimensions - Diffuser3 inches x 15 1/8 inches (flush), Diffuser Rough Opening 1 1/4 inches Height x 13 5/8 inches Width Blower Grille 7 3/4 inches x 15 3/4 inches (flush) Blower Rough Opening 4 7/8 inches Height x 13 7/8 inches Width

Staggered intake and discharge stop light and reduce room to room sound transfer

Requires hard wiring to 120 VAC. Requires wall switch or thermostat (not included)

Customer Reviews

****** - Verified Buyer

MY NEEDI have a closet I use for all my electronics. There are two servers, a DirecTV box, a receiver, a XBOX One and all of my networking equipment. In all, they give out enough heat to raise the temperature of the closet by about 30 degrees with the doors shut. We had too find a solution other than leaving the door open all the time.INSTALLATIONInstallation is very easy. The kit comes with a cutting diagram to make the proper cuts on both sides of the wall. You will need to find the studs, because the fan needs most of the space between the studs. Also, you will need to offset the supply and return sides vertically. The fan blows air into the dead space between the studs, the supply then catches this positive pressure and exits the air from the dead space through a very small plenum. It works very well.I also installed a thermostat (see below). This was very simple. I got a thermostat that was rated for inline usage. You won't be able to use a thermostat like the one in your house, you'll need one rated for at least 110v and 15amps. Anyway, I installed this inline and the fan is working great. I just put it between the power supply and the fan.Everything you need, other than the thermostat, came in the box. Screws, plates and mounting instructions. I would suggest getting a multitool to cut the wall, it makes installation much easier. Once installed, the entire thing looks great.GENERAL REVIEWSo far, this is exactly what we were looking for. The fan is very quiet, barely noticeable at all. The supply plenum is very small, about 3 inches by 16 inches. In our installation, we put it just below the ceiling. You can feel the air if you put your hand beside it, but otherwise the hot air is dispersed very well. Because of the quiet sound and the direction of the plenum, most people don't even notice it all.As for the fan's ability to exhaust the air from the server closet, it works very well. It creates enough negative air pressure to pull the air from under the door, but still keep enough air moving to cool the room. If your room is sealed tight, you will need to figure out a way to get air into this room through another opening, but for us, the space between the door and the floor has been enough.THERMOSTATIn case you would like a thermostat, this one works:http://www.amazon.com/gp/product/B000E7BTFO/ref=oh_aui_detailpage_o09_s00?ie=UTF8&psc=1The manufacturer has a wireless thermostat is likes to sell, but it is unnecessary if you want to do the wiring yourself (and it costs over 100 bucks). Since the thermostat above is a lot cheaper, I chose it. I installed it so the fan would cutoff when the closet is below the temperature I feel is safe. Although the thermostat feels a little redundant now because the servers put out more sound than this fan does. It really is very quiet. I wouldn't mind just leaving it on all the time, but I went ahead and installed the thermostat.